Local Velocity Measurement
Method: Electromagnetic (Faraday's Law)
Range: -5 to +20 ft/s (-1.5 to +6.1 m/s)
Accuracy: ±2% of reading ± zero stability at -3 to +10 ft/s (-0.9 to
+3 m/s)
Zero Stability: ±0.05 ft/s (±15.2 mm/s)
Resolution: 0.01 ft/s (3.05 mm/s)
Level Measurement
Method: Submerged pressure transducer
Range: 0.4 - 138 inches (1.0 to 350 cm)
Contact factory for extended ranges.
Accuracy: (Includes non-linearity, hysteresis, and velocity effects)
±0.25 inches (0.64 cm) -3 to +10 ft/s
(-0.9 to +3 m/s)
Temperature Effects: ±0.25 inches (0.64 cm) ±0.75% of reading over
40° to 113°F (5° to 45°C)
Resolution: 0.1 inch (.25 cm)
Over Range Protection: 2 X range
Flow Calculation
Method: Conversion of water level and pipe size to fluid area;
Conversion of local velocity reading to mean velocity; Multiplication
of fluid area by mean velocity to equal flow rate.
Conversion Accuracy: ±2% of reading (Assumes pipe is 10 to 90% full
and a level greater than 2 inches)*
*Proper site selection, sensor placement and flow profiling are
recommended to achieve highest instrument accuracy.
Intrinsically Safe Version
Certified to UL913, 4th Edition, Category 16, Class I, Div.1, Groups
A, B, C, D - Contact factory for specifications.
Housing
Modified NEMA 4X Fiber-reinforced polyester with clear polycarbonate
cover.
Dimensions: 12.5"H x 10.5"W x 8"D
32.4 x 26.5 x 20.2 cm.
Power Requirements
110 volts/60 Hz or 220 volts/50 Hz
Outputs
- LCD backlit display with contrast adjustment.
- Contact Closure: Isolated Form C relay. 28 VDC @ 1 amp, 120 VAC @
0.3A
- 4-20 mA: 600 ohms
Weight
10 lbs. (5 kg) without sensor
13 lbs. (6 kg) with sensor
Display
Keypad: 19 key numeric/control keypad for site set-up of flowmeter via
menu driven software. Selections include flow rate, flow total,
velocity, and/or level.
Operating Temperature Range
Electronics: -40° to 122°F (-40° to 50°C)
Standard Sensor: 32° to 113°F (0° to 45°C)
Optional Sensor: 32° to 150°F (0° to 66°C)
Relative Humidity: 10-90%, non- condensing
Safety Standard
Meets ANSI/ISA-S82.01-1988 and S82.03-1988.
Materials
Sensor: Polyurethane exposed to flow
Cable: 30 ft. (9.14 m) Polyurethane jacket
Mounting Hardware: 304 stainless steel
Ordering Information
Standard Model 253
flowmeter includes modified NEMA 4X electronics enclosure with clear
cover, electromagnetic velocity/level sensor with non-fouling
electrodes, 30' sensor cable, two backlit LCD displays (one display
for totalized flow and one display for level, velocity, and flow), 19
key numerical keypad, site set-up of flowmeter via menu-driven
software, one flow proportional contact closure, one 4-20 mA output of
flow rate, electronics heater, password protection, battery back-up,
and one instruction manual.
Intrinsically Safe Option
includes Certified Intrinsically Safe version that includes an
Intrinsically Safe Sensor Barrier (ISSI) with 50' of interconnection
cable to the electronics package and includes the Intrinsically Safe
Interface with ceramic sensor with 90° cable exit available with 30'
or 60' of sensor cable or Intrinsically Safe Interface with ceramic
sensor with 45° cable exit available with 30' or 60' of sensor cable.
Options include
additional 4-20 mA outputs of velocity and/or level, extended sensor
cable available in 20' increments with maximum un-spliced cable length
of 100' and maximum cable length spliced 500' - Not applicable to CE
Packaged or Intrinsically Safe units, sun shield, stainless steel
tags, ceramic sensor, extended level range, choice of 12 or 24 VDC
input power and additional instruction manuals.
Contact factory for Sensor
Mounting Hardware Ordering Information