Focus On Flow
 
Our Free Newsletter 
Sign Up Now!

 

dot dot Model 253 Specifications

Home
Flo-Mate
Flo-Tote 3
Flo-System
Flo-Dar
Flo-Ware T-200 Software

 

Local Velocity Measurement
Method: Electromagnetic (Faraday's Law)
Range: -5 to +20 ft/s (-1.5 to +6.1 m/s)
Accuracy: ±2% of reading ± zero stability at -3 to +10 ft/s (-0.9 to +3 m/s)
Zero Stability: ±0.05 ft/s (±15.2 mm/s)
Resolution: 0.01 ft/s (3.05 mm/s)

Level Measurement
Method: Submerged pressure transducer
Range: 0.4 - 138 inches (1.0 to 350 cm)
Contact factory for extended ranges.
Accuracy: (Includes non-linearity, hysteresis, and velocity effects) ±0.25 inches (0.64 cm) -3 to +10 ft/s
(-0.9 to +3 m/s)
Temperature Effects: ±0.25 inches (0.64 cm) ±0.75% of reading over 40° to 113°F (5° to 45°C)
Resolution: 0.1 inch (.25 cm)
Over Range Protection: 2 X range

Flow Calculation
Method: Conversion of water level and pipe size to fluid area; Conversion of local velocity reading to mean velocity; Multiplication of fluid area by mean velocity to equal flow rate.
Conversion Accuracy: ±2% of reading (Assumes pipe is 10 to 90% full and a level greater than 2 inches)*
*Proper site selection, sensor placement and flow profiling are recommended to achieve highest instrument accuracy.

Intrinsically Safe Version
Certified to UL913, 4th Edition, Category 16, Class I, Div.1, Groups A, B, C, D - Contact factory for specifications.

Housing
Modified NEMA 4X Fiber-reinforced polyester with clear polycarbonate cover.
Dimensions: 12.5"H x 10.5"W x 8"D
32.4 x 26.5 x 20.2 cm.

Power Requirements
110 volts/60 Hz or 220 volts/50 Hz

Outputs
- LCD backlit display with contrast adjustment.
- Contact Closure: Isolated Form C relay. 28 VDC @ 1 amp, 120 VAC @ 0.3A
- 4-20 mA: 600 ohms

Weight
10 lbs. (5 kg) without sensor
13 lbs. (6 kg) with sensor

Display
Keypad: 19 key numeric/control keypad for site set-up of flowmeter via menu driven software. Selections include flow rate, flow total, velocity, and/or level.

Operating Temperature Range
Electronics: -40° to 122°F (-40° to 50°C)
Standard Sensor: 32° to 113°F (0° to 45°C)
Optional Sensor:  32° to 150°F (0° to 66°C)
Relative Humidity: 10-90%, non- condensing

Safety Standard
Meets ANSI/ISA-S82.01-1988 and S82.03-1988.

Materials
Sensor: Polyurethane exposed to flow
Cable: 30 ft. (9.14 m) Polyurethane jacket
Mounting Hardware: 304 stainless steel

Ordering Information

Standard Model 253 flowmeter includes modified NEMA 4X electronics enclosure with clear cover, electromagnetic velocity/level sensor with non-fouling electrodes, 30' sensor cable, two backlit LCD displays (one display for totalized flow and one display for level, velocity, and flow), 19 key numerical keypad, site set-up of flowmeter via menu-driven software, one flow proportional contact closure, one 4-20 mA output of flow rate, electronics heater, password protection, battery back-up, and one instruction manual.

Intrinsically Safe Option includes Certified Intrinsically Safe version that includes an Intrinsically Safe Sensor Barrier (ISSI) with 50' of interconnection cable to the electronics package and includes the Intrinsically Safe Interface with ceramic sensor with 90° cable exit available with 30' or 60' of sensor cable or Intrinsically Safe Interface with ceramic sensor with 45° cable exit available with 30' or 60' of sensor cable.

Options include additional 4-20 mA outputs of velocity and/or level, extended sensor cable available in 20' increments with maximum un-spliced cable length of 100' and maximum cable length spliced 500' - Not applicable to CE Packaged or Intrinsically Safe units, sun shield, stainless steel tags, ceramic sensor, extended level range, choice of 12 or 24 VDC input power and additional instruction manuals.

Contact factory for Sensor Mounting Hardware Ordering Information

 

dot dot

Model 253 Specifications

dot

 
Address: Marsh-McBirney, Inc. 4539 Metropolitan Ct. Frederick, Maryland 21704 USA
Telephone:
U.S. and Canada 1-800-368-2723 - Outside the U.S. 1-301-874-5599 - Fax: 1-301-874-2172

Copyright Marsh-McBirney, Inc.  All rights reserved.