| Permanent AC Powered
Monitor
Graphic Display
 | Passive matrix color LCD |
 | 320 x 240 quarter VGA |
 | Dimensions - 4.6" x
3.6"
(11.7 cm x 9.14 cm) |
 | Displays flow rate, flow,
totals, average velocity and level. |
Data Entry
 | Touch screen keypad |
 | Menu-driven programming |
Time base accuracy
 | 1 second per day |
Outputs
 | 4-20 mA outputs: First isolated up to 600 ohm load.
Second requires optional isolator.
 | Two (2) outputs standard |
 | Each output selectable
between
flow rate, velocity or level. |
|
 | Contact Closure - one form C dry
contact closure
 | Selectable for either flow
proportional or alarm for either flow rate, velocity or
level. |
|
 | Rating: 1A 30VDC (resistive)
0.5A 125 VAC (resistive) |
Power Requirements
 | AC: 85-264 VAC, 47-63 Hz, 32
watts |
Enclosure
 | Material: NEMA 4, ABS Plastic |
Dimensions
 | 10.2" W x 13" H
x 7.25" D
(25.9 cm W x 33 cm H x 18.4 cm D)
(with mounting bracket in place) |
Weight
 | 7.5 lbs. (3.4 kg) |
Temperature Operating
Range
 | 14° F to 122° F (-10° C to
50° C)
(relative humidity non-condensing 10-90%) |
Storage Temperature
 | -40° F to 140° F
(-40° C to 60° C) |
|
|
Flo-Dar Sensor Specification
Model 450, Model 464, Model 460
Enclosure
 | Material: Polystyrene |
 | Dimensions: 6.9" W x 16.65" L x 11.7" D
(17.5 cm x 42.3 cm x 29.7 cm) |
 | Weight: 10.5 lbs (4.8kg) |
 | Temperature Operating Range: 14° F to 122° F (-10° C to 50° C) |
 | Storage Range: -40° F to 140° F (-40° C to 60° C) |
 | Sensor Cable Material: Polyurethane jacketed Standard Length: 30' (9.14m),
maximum 1000' (304.8 m) Disconnectable at both sensor and monitor |
Velocity Measurement
 | Method: Radar Range: 0.75 to 20 ft/s (0.23 m/s to 6.10 m/s) |
 | Accuracy: ±0.5%; ±0.1 ft/s (±0.03 m/s) |
Level Measurement
 | Method: Ultrasonic Operating Range: 0.25 to 60 in. (0.634 to 152.4 cm) |
 | Temperature Compensated Accuracy: ±0.25 in. (±0.64 cm) 1% Accuracy |
Surcharge Level Measurement
 | Method: Piezo-resistive pressure transducer |
 | Maximum Range: 138 inches (3.5 meters) |
Flow Measurement
 | Based on Continuity Equation. Accuracy: ±5.0% of reading typical where
flow is in a channel with uniform flow conditions and is not surcharged. |
|
|
|
 |
|