SENSOR
Velocity Measurement
Method: Electromagnetic (Faraday’s Law)
Range: -5 to +20 feet per second (-1.5 to
+6.1m/s)
Accuracy: ±2% of reading, ± 0.05 zero
stability at 0 to +10 ft/sec (0 to + 3m/sec)
Zero Stability: ±0.05 feet per second
(±0.015m/sec)
Resolution: 0.01 feet per second (±
0.003m/sec)
Level Measurement
Method: Submerged pressure transducer
Range: Standard 0.4 to 138 inches. (10mm to
3.5m) Optional 0.4 to 276 inches
Accuracy: ±1% of reading
Zero Stability: ± 0.03 ft. (± 0.009m) zero
stability for 0 to 10 ft (0 to 3m). Includes non-linearity, hysteresis and
velocity effects.
Resolution: 0.1 inch (2.5mm)
Over Range Protection: 2 X range
Flow Measurement
Method: Conversion of water level and pipe
size to fluid area. Conversion of local velocity reading to mean velocity.
Multiplication of fluid area by mean velocity to equal flow rate.
Conversion Accuracy: ±5.0% of reading.
Assumes pipe is 10 to 90% full and with a level greater than 2 inches
Temperature Measurement:
Method: 1 wire digital thermometer
Range: 14º to 185ºF (-10º to 85º C)
Accuracy: ± 6 F (3.5C) degrees
Material
Standard: Polyurethane
Dimensions: 5 3/16"(131.8mm) L, 1 ¾ "
(44.5mm)W, 1 1/8" H (29mm)
Weight: 2.5 lbs. (with 30 feet of sensor
cable)
Operating Temperature Range: 32° to 113° F
(0° to 45° C)
Storage Temperature: -4º to 125º F (-20° to
52°C)
Sensor Cable
Material: Polyurethane jacketed
Standard Length: 30 ft. (9m)
Optional Length: 60 ft. (18m),100 ft.
(30m) or length as needed (maximum 1000 ft/300m)

FLO- LOGGER
Data Storage
64K (16K cycles of velocity/level data)
Local Terminal
RS232C at 19.2K baud
Power Requirements
Two 6-volt lantern batteries
Battery Life
Typical - 16 weeks at a sample interval of 15
minutes (with recommended batteries)
Housing
Sealed watertight PVC – meets IP68 rating
Length: 13.85 in. (35.179 cm)
Diameter: 7.75 in. (19.685 cm)
Weight: 7.5 lbs. (3.4 kg) (including
batteries)
Temperature
Operating Range: 14° F to 125° F (-10° C to
51° C)
Storage Temperature Range: -4° F to 125° F
(-20° C to 51° C)
Sensor/Logger Disconnect
Both the sensor and the logger have
waterproof (IP68) connectors for easy separation from the interconnecting
cable.
Certification
FCC Rules Part 15
Industry Canada RSS 210
No user license required.

FLO-STATION
Data Storage
64K (16K cycles of velocity/level data)
Local Terminal
RS232C at 19.2K baud
Outputs
(4) 4-20 mA isolated outputs scaleable to
desired values and capable of sinking 50 ohms each. Contact Closure (One
form C dry).
Power Requirements
+12VDC @220 mA with three 4-20mA
outputs @ 20Ma
Housing
NEMA 4X (IP66/67-7)
Material: Polystyrene
Dimensions: 9 in. W x 7 in. H x 4 in. D
(229 mm W x 178 mm H x 102 mm D)
Weight: 2.75 lbs. (1.25 kg)
Temperature
Operating Temperature Range: 14° to 122°F
(-10° C to 50° C)
Storage Temperature Range: -4° to 122°F
(20° C to 50° C)